Kab ignifuge ki ba lafimen dife

Ignifuge dife kab lafimen ki ba se yon kalite espesyal nan kab ki efektivman siprime pwopagasyon flanm dife pandan yon dife pandan y ap pwodui anpil lafimen pandan konbisyon.
Voye rechèch
Dekri teren

Pwodwi Deskripsyon

 

Câbles ignifuge ki ba lafimen faktori nou yo sitou gen lafimen ki ba ak alojene -gratis. Kab sa yo pa gen materyèl alojene tankou klò ak brom, epi yo pa lage gaz toksik oswa korozivite lè boule, kidonk evite domaj segondè nan pèsonèl ak ekipman.

product-400-400

 

Modèl pwodwi

 

Nimewo Modèl

Non konplè

Materyèl izolasyon

Materyèl djenn

Evalyasyon ignifuge flanm dife

Rezistans dife

Alojene ki ba lafimen-gratis

WDZ-BYJ

Halogen -gratis, ki ba-fimen, flanm dife-ignifuge nwayo kwiv kwa-lye fil polyethylene izole

XLPE

Poliolefin ki pa gen -lafimen alojene-

ZC

Non

Wi

WDZB-BYJ

Klas B flanm dife-ignifuge alojene-gratis ki ba-fil lafimen

XLPE

ZB

Non

Wi

WDZA-BYJ

Klas A -ignifuge alojene-gratis ki ba-fil lafimen

XLPE

ZA

Non

Wi

WDZ-YJY

Kab alojèn-gratis, ki ba-lafimen, flanm dife-rezistan

XLPE

ZB/ZC

Non

Wi

WDZB-YJY 3×25+1×16

Klas B flanm dife-ignifuge, ki ba-fimen, alojene- kab pouvwa gratis

XLPE

ZB

Non

Wi

WDZN-YJY

Kab alojèn-gratis, ki ba-lafimen,-ignifuge, dife-rezistan

XLPE

ZB

Wi (950 degre, 90min)

Wi

WDZAN-YJY

Klas A flanm-ignifuge + dife-rezistan ba-lafimen alojene-lib kab

XLPE

ZA

Wi (950 degre, 180min)

Wi

WDZ-BYJF

Fil ki gen alojene-ki -ki lye kwaze ki irradie, ki ba-fimen, ki gen okenn fil-ignifuge flanm dife

辐照XLPE

ZC

Non

Wi

WDZB-BYJ 185mm²

Gwo -seksyon flanm-ignifuge ki ba-fil lafimen

XLPE

ZB

Non

Wi

 

Karakteristik pwodwi ak aplikasyon

 

1. Kab-ignifuge ki ba-lafimen nou an ka kenbe tèt ak yon tan -tanperati fonksyònman alontèm 150 degre, ak limit tanperati kout -tèm jiska 180 degre. Kapasite kontinyèl akseptab aktyèl li yo se 1.5 a 1.6 fwa sa yo ki nan kondiktè òdinè nan menm spesifikasyon.

2. Nan tanperati chanm, kab lafimen dife -ignifuge ki ba- nou an gen menm fòs ak fil aliminyòm òdinè, ak pousantaj retansyon fòs mekanik li nan tanperati ki wo ka rete pi wo pase 90%.

3. Kab lafimen -ignifuge ki ba- nou an te sibi tès espre sèl nan laboratwa ak tès ekspoze atmosferik deyò, ki pa montre okenn diferans enpòtan ant de la.

4. Kab lafimen dife -ignifuge ki ba- nou an pèmèt yon reyon koube 30 fwa dyamèt kab la.

5. Anplis de konpozan alyaj nan kondiktè sa a amelyore pèfòmans segondè -tanperati li yo. Ansanm, seksyon transvèsal -kondiktè ogmante ogmante kapasite aktyèl la, amelyore konduktivite, epi redwi pèt yo. Sa a diminye konsomasyon pouvwa ak amelyore sekirite ekipman yo.

 

Pwodwi paramèt teknik

 

Seksyon transvèsal nominal - aliminyòm (mm²)

Seksyon kalkil (mm²)

Kantite monofilaman (n)

Dyamèt (mm)

Mas pa inite longè (kg/km)

Fòs kraze nominale (kN)

DC rezistans (20 degre)
(Ω/km)

Monofilaman

Fil trese

10

10.0

7

1.35

4.05

27.4

1.69

2.8578

16

16.1

7

1.71

5.10

43.9

2.72

1.7812

25

24.9

7

2.13

6.5

68.1

4.22

1.1480

35

34.4

7

2.50

7.5

93.8

5.81

0.8333

40

40.1

7

2.7

8.1

109.4

6.65

0.7144

50

49.5

7

3.00

9.0

135.1

8.02

0.5787

63

63.2

7

3.39

10.2

172.5

10.24

0.4532

70

71.3

7

3.60

10.8

194.5

11.54

0.4019

95

95.1

7

4.16

12.5

259.8

15.13

0.3010

100

100.1

19

2.59

13.0

274.9

16.92

0.2874

120

121.2

19

2.85

14.3

332.8

20.12

0.2374

125

124.6

19

2.89

14.5

342.3

20.69

0.2309

150

148.1

19

3.15

15.8

406.6

23.99

0.1943

160

159.6

19

3.27

16.4

438.2

25.85

0.1803

185

182.8

19

3.50

17.5

502.0

29.61

0.1574

200

199.9

19

3.66

18.3

548.9

32.38

0.1439

210

209.8

19

3.75

18.8

576.3

34.00

0.1371

240

238.8

19

4.00

20.0

655.6

37.96

0.1205

250

249.6

19

4.09

20.5

685.5

39.69

0.1153

300

297.6

37

3.20

22.4

819.4

48.21

0.0969

315

314.5

37

3.29

23.0

866.1

50.96

0.0917

400

400.0

37

3.71

26.0

1101.4

64.80

0.0721

450

451.1

37

3.94

27.6

1242.2

71.73

0.0639

500

500.5

37

4.15

29.1

1378.1

79.58

0.0576

560

560.0

37

4.39

30.7

1542.1

89.05

0.0515

630

631.3

61

3.63

32.7

1741.2

102.27

0.0458

710

710.1

61

3.85

34.7

1958.7

112.91

0.0407

800

801.4

61

4.09

36.8

2210.5

127.43

0.0360

900

898.2

61

4.33

39.0

2477.5

142.82

0.0322

1000

1000.6

61

4.57

41.1

2759.8

159.09

0.0289

 

FAQ

 

Ki sa ki konsiderasyon kle yo lè w ap achte câbles ignifuge ki ba lafimen?

  • Lè w ap achte câbles ignifuge ki ba lafimen, li enpòtan pou respekte twa prensip prensipal yo: sètifikasyon konfòmite, matche senaryo, ak verifikasyon materyèl. Premyèman, detèmine evalyasyon ki apwopriye a ki baze sou senaryo a. Pou zòn ki gen anpil moun, kab alojene-gratis, ki ba-lafimen ak yon evalyasyon ignifuge nan Klas A oswa B yo obligatwa. Pou bilding rezidansyèl òdinè, kab klas C yo ka chwazi pou balanse depans yo.
  • Dezyèmman, sikui-konbat dife kritik yo dwe genyen tou pwopriyete ki reziste dife-.
  • Finalman, sevè verifye otantisite materyèl yo. Segondè -kab bon jan kalite yo ta dwe gen gwo-kondiktè kwiv pite ak izolasyon kwa-lye polyolefin, ak yon santiman lis ak fleksib. Fè atansyon ak pri ki ba twòp, sa ki ka endike nwayo kòb kwiv mete adiltè oswa alojene-ki gen djenn. Mande yon twazyèm pati -rapò tès dansite lafimen ak endèks toksisite.

Baj popilè: ignifuge dife ba lafimen kab, Lachin dife ignifuge ba lafimen kab manifaktirè yo, ke founisè, faktori